Sysmex Nederland
Menu

Starrsed Interrliner XN

The Interrliner XN, also known as Starrsed RL, makes continuous production of the ESR analyses available, as a segment within a complete production line or as a stand-alone instrument. Easy loading of the samples from the racks into the instrument. Fully automatic barcode reading for an optimum co-operation with the administration- and report software. Fully automated preparation of samples before aspiration.The Interrliner XN works with our standard Sysmex blood cell counter racks and performs dedicated ESR measurements fully unattended. Direct interfacing/ integration between the Sysmex XN-Series (XN-9100) and Interrliner XN is possible. RR Mechatronics developed the Starrsed RL according to the Sysmex XN-Series appearance, rack handling, software integration and outlook. However, the InteRRliner is an independent system, also capable of stand-alone operation.

Westergren Sedimentation Method
One of the oldest and most frequently requested blood tests is ESR. It has not changed fundamentally in the way it is carried out since Westergren described it in 1921. In 2011, the International Council for Standardization in Hematology (ICSH) and the Clinical and Laboratory Standards Institute (CLSI) defined the Reference Method for ESR to be the Westergren Method; the Gold Standard. The objective of ESR testing is to measure inflammatory state. The Westergren Method measures both infections related to infectious diseases and chronic inflammatory conditions. In addition to being very reliable, the Westergren Sedimentation Method is also amongst the cheapest laboratory tests available.

Spécifications
Measurement principle Westergren gold standard - CLSI H02-A5 (2011): Procedures for the Erythrocyte Sedimentation Rate Test. Approved Standard – Fifth Edition. Vol. 31 No. 11, Jou JM et al. (2011): ICSH review of the measurement of the erythrocyte sedimentation rate. Int J Lab Hematol. 33:125 – 132 and Kratz A et al. (2017): ICSH recommendations for modified and alternate methods measuring the erythrocyte sedimentation rate. Int J Lab Hematol. 39(5) : 448 – 457.
Aspiration volume 1.4 mL of whole blood   
Throughput Single Interrliner: 140 samples per hour
Double Interrliner: 240 samples per hour
Triple Interrliner: 360 samples per hour
Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nederland B.V.

Ecustraat 11

4879 NP Etten-Leur

The Netherlands

+31 (0)76 508 6000

+31 (0)76 508 6086

Sysmex Belgium N.V.

Chaussée de Bruxelles 135A

1310 La Hulpe

Belgium

+32 (0)2 769 7474

+32 (0)2 7697499

En savoir plus

Copyright © Sysmex Europe SE. All rights reserved.