The FIT-based screening test is easy and therefore manages to attract high participation rates – the main driver behind the success of any national or regional screening programme. Generally, national or regional administrations assume responsibility for managing the logistics, financials and efficiency of the programme in close cooperation with their selected laboratory partners.

For further information, you can check our FIT for screening microsite. 
www.fitscreening.eu/

 

 

Sysmex XN-2000

XN-2000

  • 200 samples/h
  • Sampler capacity 10 racks
  • Choose diagnostic APPs as needed
  • Integrated backup concept
  • Short turnaround times

Documents

All
  • All
  • Literature
Documents

XN-2000 - a perfect pair for basic and extended testing

The XN-2000 system is a combination of two analysis modules that you can equip with a specified clinical application. In its Rerun & Reflex configuration, it is transformed into a superb solution for basic and extended testing. Because the two modules process rack samples simultaneously, it can accommodate any sample without slowing down. The modules work together perfectly. And you don’t lose any precious time, even with abnormal samples.

With integrated reflex testing, you no longer have to select and reload samples manually. The reflex sampler feeds the samples into the left-hand module automatically and performs the extended measurement. If there are no abnormal samples, it speeds up the system by working on standard samples instead.

Having two modules up and running means you have greater security for daily routines as you always have an integrated back-up solution at your disposal. To enhance the scope of your labs, you can network your XN-2000 with other XNs to create multiple-location installations. This lets you couple specialised and central laboratory units, and increase your service offering. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime.

Request a quote

Specifications

Specifications

Measurement principles
WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry 
RBC/PLT: Hydrodynamically focussed impedance 
HGB: Cyanide-free SLS haemoglobin

Aspiration volume    
88 µL in whole blood (WB) mode and body fluid (BF) mode

Throughput
Up to 200 samples/h

Quality control   
XN Check (three levels) and XN Check BF (two levels)

Configurations
XN-2000 [DIFF] 
XN-2000 [WPC]

Parameters

Parameters

XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood
WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)
PLT-F, IPF, IPF#With WPC (optional) Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence
HPC%, HPC#

Body Fluids with XN-BF
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#(optional)