Sysmex Nederland
Menu

geneLEAD VIII

Compact, user-friendly and fast: the geneLEAD® VIII streamlines your workflow by delivering results for up to eight samples in just 120 minutes. Its fully automated process ensures ease of use, while networking up to six independent devices offers flexibility and scalability for daily lab needs. GeneLEAD® VIII is IVDR certified for compliance with the latest regulatory standards1 and includes HEPA filter and UV light for a robust contamination prevention.

The geneLEAD® system includes 8 independent, fully automated tracks, each consisting of:

  • Robust extraction module for separation of the nucleic acid using magnetic beads, from cellular materials, contaminants, and other impurities.
  • Independent real-time PCR module equipped with 6 fluorescent channels to detect all required SMD Lead Kits’ targets in one reaction mix.

Extraction and real-time PCR can be used either together or separately.

Results are analysed and reported directly using the geneLEAD® software and can be accessed on the device’s laptop or remotely via the LIS system. 

Specifications
Dimensions / weights
W x H x D [mm / kg]
35 × 70 × 77 cm ( L W H )
80 kg
Device Type: Benchtop sample-to-result PCR system
Sample Throughput (Single Device): Up to 8 samples (batch procedure)
Technology Real-Time PCR

Detection System:

6 fluorescence channels (FAM, Channel 1; HEX, Channel 2; ROX, Channel 3; Cy5, Channel 4; TAMRA, Channel 5; Cy5.5, Channel 6)

Thermal Control:

An independently controlled thermocycler
Temperature range: 40 to 99 °C
Heating rate: 3-4 °C/sec
Extraction temperature: approx. 65 to 80°C
Volumes Sample volume: 200 μL
Elution volume: 100 μL
PCR volume: 25 μL
Laptop & Software Notebook PC for geneLEAD® VIII including geneLEAD® VIII Software
LIS (Laboratory Information System) connectable
included with geneLEAD VIII 
Consumables
  • magDEA Dx SV Nucleic acid extraction cartridge (product no. E1300) 
  • geneLEAD VIII Consumable Set (product no. F8900)
  • geneLEAD VIII PCR Reaction Cassette Set (product no. F8840)
to be purchased separately
Power Supply:
  • AC 100-120 V or AC 220-240 V
  • Frequency range: 50 Hz to 60 Hz
  • Power consumption: approx. 400 VA
Contamination control
  • UV light decontamination
  • HEPA filter
Contact
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Nederland B.V.

Ecustraat 11

4879 NP Etten-Leur

The Netherlands

+31 (0)76 508 6000

+31 (0)76 508 6086

Sysmex Belgium N.V.

Chaussée de Bruxelles 135A

1310 La Hulpe

Belgium

+32 (0)2 769 7474

+32 (0)2 7697499

Explore more

CALiaGold

CALiaGold

Quantitative latex immunoassay for calprotectin measurement

Details
Multiprobe Range

Multiprobe Range

Cytocell - Multiprobe Range

Details
FOB Gold pierce tube

FOB Gold pierce tube

From faecal sample collection to direct analysis.

Details
Copyright © Sysmex Europe SE. All rights reserved.