The FIT-based screening test is easy and therefore manages to attract high participation rates – the main driver behind the success of any national or regional screening programme. Generally, national or regional administrations assume responsibility for managing the logistics, financials and efficiency of the programme in close cooperation with their selected laboratory partners.

For further information, you can check our FIT for screening microsite. 
www.fitscreening.eu/

 

 

OMNISEC RESOLVE

  • Complete gel permeation/size exclusion chromatography (GPC/SEC) solution consisting of systems, detectors and software
  • Most sensitive and accurate multi detector GPC/SEC system
  • For absolute weight and molecular weight distribution, intrinsic viscosity and molecular structure, sample concentration, etc.
  • Flexible autosampler with temperature control
  • Workflow oriented software

Documents

All
  • All
  • Brochure
Documents

Combined pump, degasser, autosampler and column oven, for high quality GPC/SEC and accurate molecular weight measurement

OMNISEC RESOLVE combines with OMNISEC REVEAL to form a complete OMNISEC GPC/SEC solution for the measurement of absolute molecular weight, intrinsic viscosity and other parameters. It combines an integrated pump, degasser, autosampler and column oven in a single advanced separations unit.

OMNISEC RESOLVE has been designed using our 30 years of experience in GPC/SEC to achieve the highest possible standard in chromatographic performance. The efficient degasser, low-pulsation pump and column oven combine to give reduced baseline noise, which maximizes measurement sensitivity and accuracy.

With OMNISEC RESOLVE you can:

  • Achieve superior baseline stability in all detectors with its efficient degasser and pump flow rate stability
  • Reduce sample usage with low injection volumes and waste-free injections from vials or 96-well microtiter plates
  • Protect thermolabile samples such as proteins from aggregation in the cooled autosampler
  • Rapidly switch between many applications, solvents and buffers, thanks to its efficient, low-volume degasser and automated pump priming
  • Make separations in viscous solvents such as DMF and DMSO thanks to the column oven and autosampler temperature control
  • Reduce service requirements thanks to continuous pump seal back washing

Request a quote

Specfications

Specfications

System
Pump flow rate: 0.005 - 10 mL/min
Flow rate accuracy: ±1%
Pressure range: 0 - 5000 PSI (34.5 MPa)
Pulsation: 0.15% @ 1 mL/min in water
Dimensions: 420 (W) x 640 (D) x 890 (H) mm
Weight: 62 kg

Autosampler
Capacity: Up to 192
Sample container types: HPLC vials or 96-well microtiter plates
Injection volume: 1 - 300 µL
Injection volume accuracy: >99.5%

Injection volume precision
<0.3% RSD in full loop mode 
<0.5% RSD in partial loop mode
<1% RSD in µL pickup mode

Injection overhead volume: 0 µL in µL pickup mode
Syringe volume: 250 µL standard
Temperature control range: 4 - 60 °C

Column oven
Column capacity:6 x analytical (1 x Tricorn 10/300 GL)
Temperature control range:20 - 65 °C