JAI Gradient HPLC Systems

  • Gradient function is now added to LC-91 NEXT series with high reliability. Isocratic Recycle module is also supported as always.
  • Quaternary Low-Pressure Gradient
  • Non-diffusion device (patent) that prevents the sample from running back into the solvent line
  • Large size LCD tough panel for easy operation
  • LC-9110G NEXT 0,001 - 10,00ml /min
    LC-9130G NEXT 0,001 - 30,00ml /min

Documents

All
  • All
  • Brochure
Documents

JAI Gradient HPLC Systems

Addition of Gradient Module
Gradient function is now added to LC-91NEXT series with high reliability. Isocratic Recycle module is also supported as always

Quaternary Low-Pressure Gradient
Installed Low-pressure gradient module offers a blend of 4 different solvents. Combination of recycle after gradient mode separation expands the application range in separation and purification of compounds with a wide polarity range.

Recycle with Non-diffusion (patent)
During an extended recycling period, the recycled Recycle valve sample in the flow line may diffuse back into the solvent with the danger of contaminating the solvent reservoir. The NEXTseries has non-diffusion device (patent) that prevents the sample from running back into the solvent line and damaging

Large size LCD touch panel for easy operation
An 8.4 inch size touch panel screen enables easy and user-intuitive operation with the flow channel diagram on the screen. Gradient / Isocratic mode switching is super easy by simply touching icons on the screen.

Reliable solvent delivery performance
The serial double plunger pump suits recycling separation the best. With the addition of a digital flow rate compensation function, enables reliable solvent delivery performance. The exact flow rate  is guaranteed to the set value, regardless of column pressure.

Auto cleanup function
Keeps the flow channels clean automatically. Solvent changeover when changing columns is also made much easier.

Detectors
Two different types of detectors are both small enough to fit into NEXT series body. They can be installed together and perform detection simultaneously.

Specifications

Specifications

Pump Type
Reciprocating double plunger

Flow Rate
LC-9110Ⅱ NEXT
0.01 - 10.00ml /min

LC-9160Ⅱ NEXT
0.01 - 60.00ml /min

Maximum Discharge Pressure
LC-9110Ⅱ NEXT
30MPa(0.01 - 5.00ml /min)
25MPa(5.01 - 10.00ml /min)

LC-9160Ⅱ NEXT
20MPa(0.01 - 30.00ml /min)
10MPa(30.01 - 60.00ml/min)

Plunger
Φ4.0mm

Stroke
8mm

Discharge rate per stroke
LC-9110Ⅱ NEXT
100µl

LC-9160Ⅱ NEXT
300µl

Flow Stability
CV less than 0.3

Gradient Method
Low-pressure mixture method

Gradient solvent
4 solvents

Variable Injector (Manual)
Rheodyne 7725i

Sample Loop
LC-9110Ⅱ NEXT
3ml (standard)
5ml, 10ml (optional)

LC-9160Ⅱ NEXT
10ml (standard)
5ml, 15ml (optional)

Event Marker
Injection, Recycle and Collect

Recycle System
With non-Diffusion function Recycling system (patent)

Recycle Method
Swiching Scheme of Solenoid Valve

Auto Recycler
Built-in (1 to 99 times repetition possible)

Dimensions of Mainframe
464 (W) x 492 (H) x 504 (D) mm

Tray dimension for fraction collector
440 (W) x 325 (D) mm

Solvent rack dimension for Φ40mm column(s)
240 (W) x 650 (H) x 470 (D)

Weight 
40kg