The FIT-based screening test is easy and therefore manages to attract high participation rates – the main driver behind the success of any national or regional screening programme. Generally, national or regional administrations assume responsibility for managing the logistics, financials and efficiency of the programme in close cooperation with their selected laboratory partners.

For further information, you can check our FIT for screening microsite. 
www.fitscreening.eu/

 

 

Helena AggRAM

  • Measurement of Aggregration and Agglutination
  • Fully optimised half volume settings
  • 4 or 8 patient samples per run
  • Security through operator log on with password level protection

Platelet Aggregation and Ristocetin Cofactor Analysis

Flexibility
Customise your assay test sequence, calibration, dilutions, volumes, run times, display parameters, input additional agonists and create new screens

Powerful data handling
Automatic calculation of slope, max% aggregation, time to max aggregation, lag phase, secondary slope and area under the curve (research use only) with full manual edit options

Quality control
Levey-Jennings display of QC data based on assigned Westgard rules with integrated corrective action log

Detection principle
Light transmission and 4 channel laser optics

Request a quote

Specifications

Specifications

  • 0.0 to 2.0 O.D.
  • 650nm
  • Silicone coated glass Cuvette
  • 3.5x4.0mm coated magnet stirrer bar
  • Incubation and Reaction Temp 37°C +/- 1°C
  • Reagent Incubation
  • Graphics: -20% to 110% activity
  • Operating Environment: Temp: 15°C - 30°C. Humidity: 10 - 80%
  • Input Power: 220Vac, 50/60Hz, 1200 Watts max
  • Dimensions: 152 x 254 x 432 mms (h x w x d)
  • Weight: 6.75 Kg
  • Windows® 2000 Operating System
  • Bar Code Scanner Option
  • RS-232 serial port
  • Powerful Data Handling
  • Store, recall, edit and print data
    • Automatic calculation with manual edit
  • slope, secondary slope, lag phase, max% Agg, time to max, area under curve,
  • Quality Control Program
    • Levy-Jennings charts based on Westgard rules
    • Levy-Jennings Reports
    • Up to 8 channels (4 per module)
  • Daisy chain two modules
    • Customised System Configuration
  • Create your own screening profiles
  • Customise your method set up
  • Variable stirrer speed 500 – 1500rpm
    • Customised Report Format
  • Single or multi channel reports
  • Single or multi patient reports
  • Profile archived patient results over time
  • QC Reports
    • Log On and Password protected